Daikin Air Conditioning

User Manual & Installation Guide

Inverter Split System

Installation Guide

Tools Needed:

  • Adjustable wrench set
  • Vacuum pump with gauge manifold
  • Refrigerant scale
  • Flaring tool set
  • Tube cutter
  • Multimeter
  • Level

Step-by-Step Installation

  1. Select Installation Location: Choose a location with proper clearance (minimum 30cm from walls and ceilings) and solid mounting surface for both indoor and outdoor units.
  2. Mount Indoor Unit: Install mounting plate securely on wall, ensuring it is perfectly level. Hang indoor unit on plate.
  3. Install Outdoor Unit: Place outdoor unit on stable, level surface with proper vibration isolation pads. Ensure adequate airflow clearance.
  4. Connect Refrigerant Pipes: Connect copper pipes between indoor and outdoor units using flare connections. Ensure pipes are properly insulated.
  5. Electrical Connection: Connect power cables to appropriate terminals following wiring diagram. Connect communication cable between units.
  6. Vacuum and Charge: Evacuate system using vacuum pump for minimum 30 minutes. Charge with specified amount of R-32 refrigerant.
  7. Test Operation: Power on system and test all functions including cooling, heating, fan speeds, and remote control operation.
Warning: Installation must be performed by certified HVAC technicians only. Improper installation may cause equipment damage, personal injury, or void warranty.

Specifications

Model Series FTXM-R
Type Wall Mounted Split System
Cooling Capacity 9,000 - 24,000 BTU/h
Heating Capacity 10,000 - 26,000 BTU/h
Energy Efficiency Ratio (EER) 12.5
Seasonal Energy Efficiency Ratio (SEER) 22.5
Noise Level (Indoor/Outdoor) 19 dB / 50 dB
Refrigerant Type R-32
Power Requirements 220-240V, 50Hz, 1Ph
Indoor Unit Dimensions (HxWxD) 29.5 x 79.8 x 24.5 cm
Outdoor Unit Dimensions (HxWxD) 55 x 79.8 x 28.9 cm
Operating Temperature Range -15°C to 46°C (Cooling) / -15°C to 24°C (Heating)

Warranty Information

  • Compressor Warranty: 5 years parts and labor
  • Parts Warranty: 2 years on all components
  • Extended Warranty: Optional 10-year warranty available upon registration

For warranty service, contact Daikin Customer Service at 1-800-432-1342 or visit Daikin.com

Key Features

Inverter Technology

Daikin's advanced inverter compressor adjusts speed to match cooling/heating demand, providing precise temperature control and up to 30% energy savings compared to conventional systems.

Flash Streamer Technology

Advanced air purification system that removes allergens, bacteria, and odors from indoor air, creating a healthier living environment.

Intelligent Eye

Motion sensor detects room occupancy and adjusts operation accordingly. Energy Saver mode activates when no movement is detected for 20 minutes.

Coanda Airflow

Patiented airflow design that spreads air along the ceiling for even temperature distribution without direct drafts on occupants.

Wi-Fi Control

Connect to Daikin Mobile Controller app for remote operation, scheduling, energy monitoring, and maintenance alerts from your smartphone.

Quiet Operation

Specially designed fan blades and sound-dampening materials provide ultra-quiet operation as low as 19 dB, quieter than a whisper.

Operation Modes Explained

Auto Mode

System automatically selects cooling or heating based on room temperature for optimal comfort

Powerful Mode

Rapid cooling/heating operation for quick temperature adjustment when entering room

Econo Mode

Energy-saving operation that optimizes performance while reducing power consumption

Quiet Mode

Reduces fan speed and compressor noise for nighttime or quiet environment operation

Dry Mode

Dehumidifies air without significant cooling, ideal for humid conditions

Fan Mode

Circulates air without cooling or heating, with multiple fan speed options

Troubleshooting

Problem Possible Cause Solution
Unit not starting Power outage, circuit breaker tripped, remote control batteries dead Check power supply, reset circuit breaker, replace remote batteries
Poor cooling/heating Dirty filters, blocked airflow, refrigerant leak, outdoor unit obstructed Clean filters, clear obstructions, check for leaks, clear outdoor unit area
Water dripping indoors Clogged drain pipe, improper installation slope, dirty evaporator Clear drain pipe, ensure proper slope, clean evaporator coil
Unusual noises Loose parts, debris in fan, vibration from mounting Tighten all screws, clear debris, check mounting stability
Remote not working Dead batteries, signal obstruction, remote sensor issue Replace batteries, ensure line of sight, check indoor unit sensor
Frozen indoor unit Dirty filters, low refrigerant, fan motor failure Clean filters, check refrigerant charge, inspect fan motor

Error Codes

  • U0: Refrigerant shortage - Check for leaks and charge appropriately
  • U2: Low voltage/power failure - Check power supply and wiring
  • U4: Communication error - Check wiring between indoor/outdoor units
  • E5: Indoor unit sensor error - Replace temperature sensor
  • E6: Outdoor unit sensor error - Check outdoor unit sensors
  • H9: Outdoor temperature sensor error - Replace outdoor temp sensor
  • P1: Fan motor protection - Check fan motor and clear obstructions
  • P8: High temperature protection - Allow unit to cool before restarting

Manual Downloads

Current Model Manuals

FTXM-R

Inverter Wall Mounted Unit

FTXS-R

Premium Inverter Series

FTXJ-R

Standard Inverter Series

FTXZ-R

Ultra-Quiet Inverter Series

Popular Previous Models

FTXG-R

9,000 BTU Inverter AC

FTXM-R

12,000 BTU Inverter AC

FTXS-R

18,000 BTU Inverter AC

FTXZ-R

24,000 BTU Inverter AC

Note: For models not listed here, please visit the Daikin Support Website for complete documentation.