Daikin Ducted Air Conditioning

User Manual & Installation Guide

Inverter System

Installation Guide

Tools Needed:

  • Refrigeration manifold gauge set
  • Vacuum pump
  • Torque wrench
  • Pipe cutter and flaring tool
  • Multimeter
  • Level
  • Drill with hole saw attachment

Step-by-Step Installation

  1. Site Selection: Choose appropriate locations for indoor unit (ceiling void) and outdoor unit with proper clearances for airflow and maintenance access.
  2. Ductwork Planning: Design ductwork layout ensuring proper airflow distribution and minimal static pressure loss.
  3. Mounting Indoor Unit: Securely mount the indoor unit in ceiling void using vibration isolation mounts and ensure proper drainage slope.
  4. Refrigerant Piping: Install refrigerant lines with proper insulation, ensuring no kinks or sharp bends in piping.
  5. Electrical Connection: Connect to dedicated circuit with proper grounding according to local electrical codes.
  6. Drainage System: Install condensate drain line with proper trap and venting to prevent air lock.
  7. Outdoor Unit Installation: Place outdoor unit on stable pad with proper vibration isolation and minimum clearances.
  8. System Evacuation: Evacuate system to 500 microns or less to remove moisture and non-condensables.
  9. Commissioning: Charge with correct refrigerant amount, test all functions, and verify proper airflow at all registers.
Warning: Installation must be performed by licensed HVAC technicians only. Improper installation can cause equipment damage, reduced efficiency, and void warranty.

Specifications

Model Series FDXM-A Series
System Type Ducted Split System
Capacity Range 2.5 - 14.0 kW
Energy Efficiency Ratio (EER) Up to 4.5
Seasonal Energy Efficiency Ratio (SEER) Up to 8.5
Noise Level (Indoor/Outdoor) 19 dB(A) / 52 dB(A)
Refrigerant Type R-410A
Power Requirements 230V, 50Hz, 1Ph
Operating Temperature Range -15°C to 46°C (Cooling) / -20°C to 24°C (Heating)
Airflow (Max) Up to 1,800 m³/h
Dimensions (Indoor Unit) Varies by model (approx. 1400 x 550 x 250 mm)
Dimensions (Outdoor Unit) Varies by model (approx. 950 x 850 x 320 mm)
Communication Protocol Daikin Intelligent Touch Controller / BRP069A61

Warranty Information

  • Full Warranty: 5 years parts and labor
  • Compressor Warranty: 7 years on inverter compressor
  • Extended Warranty: Available with professional installation and registration

For warranty service, contact Daikin Customer Service at 1300 305 402 or visit Daikin.com.au

Key Features

Inverter Technology

Daikin's advanced inverter compressor adjusts speed continuously to maintain precise temperature control, reducing energy consumption by up to 30% compared to conventional systems.

Intelligent Eye

Built-in motion sensor detects room occupancy and adjusts operation to save energy when rooms are unoccupied, automatically returning to set temperature when movement is detected.

3D Airflow

Advanced airflow control allows for multi-directional air distribution, ensuring even temperature throughout the room without creating uncomfortable drafts.

Coanda Airflow

Uses ceiling surface to distribute air evenly across the room, preventing direct airflow on occupants while maintaining consistent temperature.

Daikin Intelligent Touch Controller

Wi-Fi enabled touchscreen controller with smartphone app integration for remote control, scheduling, energy monitoring, and maintenance alerts.

Powerful Heating Performance

Maintains heating capacity even at extremely low outdoor temperatures (-20°C) with Daikin's advanced defrost control system.

Operation Modes

Auto Mode

System automatically selects cooling or heating based on room temperature

Powerful Mode

Maximum capacity operation for rapid cooling or heating

Quiet Mode

Reduced fan speed for ultra-quiet operation during nighttime

Eco Mode

Energy-saving operation with optimized temperature control

Dry Mode

Dehumidification without significant cooling for humid conditions

Fan Only Mode

Air circulation without cooling or heating

Troubleshooting

Problem Possible Cause Solution
System not starting Power issue, circuit breaker tripped, controller communication error Check power supply, reset circuit breaker, ensure controller is properly connected
Poor cooling/heating performance Dirty filters, low refrigerant, blocked outdoor unit Clean filters, check refrigerant charge, clear outdoor unit obstructions
Water leakage Clogged drain line, improper drainage slope, frozen evaporator Clear drain line, ensure proper slope, check for ice formation
Unusual noises Loose parts, debris in fan, vibration transmission Tighten all fasteners, clear debris, check isolation mounts
Frequent cycling Oversized system, thermostat location, dirty filters Check system sizing, relocate thermostat if near heat source, clean filters
Error code displayed Various system faults detected Refer to error code chart in manual or contact service technician

Common Error Codes

  • U0: Refrigerant shortage - Check for leaks and refrigerant charge
  • U2: Low voltage or power failure - Check power supply and connections
  • U4: Communication error between indoor and outdoor units - Check wiring and connections
  • E5/E6: Indoor unit malfunction - Check indoor PCB and sensors
  • H8: Overload protection - Check for airflow restrictions or compressor issues
  • L5: Overcurrent protection - Check electrical components and wiring
  • F3: Discharge pipe temperature sensor error - Check sensor and connections

Manual Downloads

Current Model Manuals

FDXM50F

5.0kW Ducted Inverter System

FDXM71F

7.1kW Ducted Inverter System

FDXM100F

10.0kW Ducted Inverter System

FDXM140F

14.0kW Ducted Inverter System

Popular Previous Models

FDYQN100F

10.0kW Premium Inverter System

FDXS50F

5.0kW Standard Inverter System

FDYQ71F

7.1kW Premium Inverter System

FDXM80F

8.0kW Ducted Inverter System

Note: For models not listed here, please visit the Daikin Support Website for complete documentation and technical specifications.