Daikin Inverter Air Conditioner

User Manual & Installation Guide

FTXS Series

Installation Guide

Tools Needed:

  • Adjustable wrench
  • Level
  • Screwdrivers (flat and Phillips)
  • Pipe cutter
  • Vacuum pump
  • Manifold gauge
  • Torque wrench

Step-by-Step Installation

  1. Choose Installation Location: Select a location with proper clearance (minimum 30cm from walls and ceilings) and solid wall structure.
  2. Mount Indoor Unit: Install mounting plate securely on wall, ensuring it is perfectly level using a spirit level.
  3. Install Outdoor Unit: Place outdoor unit on stable, level surface with proper ventilation clearance (minimum 50cm all sides).
  4. Connect Refrigerant Pipes: Connect copper pipes between indoor and outdoor units using flare connections. Ensure pipes are properly insulated.
  5. Electrical Connection: Connect power cables according to local electrical codes. Ensure proper grounding and correct voltage (220-240V, 50Hz).
  6. Connect Drain Hose: Install drain hose with proper downward slope (minimum 1/100 gradient) to ensure proper drainage.
  7. Vacuum and Charge: Evacuate air and moisture from refrigerant lines using vacuum pump, then charge with specified refrigerant amount.
  8. Test Run: Run the air conditioner in cooling and heating modes to check for proper operation and refrigerant leaks.
Warning: Installation must be performed by certified HVAC technicians only. Improper installation may cause injury, damage, or void warranty.

Specifications

Model Series FTXS25FV1B / FTXS35FV1B / FTXS50FV1B
Type Wall Mounted Split System
Color White / Titanium
Cooling Capacity 2.5kW / 3.5kW / 5.0kW
Heating Capacity 3.2kW / 4.0kW / 5.8kW
Noise Level (Indoor) 19 dB(A) - 37 dB(A)
Control Type Remote Control with LCD Display
Energy Rating (Cooling) A+++
Energy Rating (Heating) A++
Refrigerant R32 (Eco-friendly)
Power Requirements 220-240V, 50Hz, 1Ph
Dimensions Indoor (HxWxD) 29.5 x 79.8 x 24.9 cm
Dimensions Outdoor (HxWxD) 55.0 x 79.5 x 28.9 cm
Weight Indoor/Outdoor 9.5 kg / 34 kg
Operating Temperature (Cooling) 18°C to 46°C outdoor
Operating Temperature (Heating) -15°C to 24°C outdoor

Warranty Information

  • Full Warranty: 3 years parts and labor
  • Compressor Warranty: 5 years on inverter compressor
  • Extended Warranty: Optional 5+3 years available with registration

For warranty service, contact Daikin Customer Service at 1-800-432-1342 or visit Daikin.com

Key Features

Inverter Technology

Daikin's advanced inverter compressor adjusts speed continuously to maintain desired temperature, reducing energy consumption by up to 30% compared to conventional units.

Coanda Airflow

Intelligent airflow control spreads cool or warm air evenly throughout the room, eliminating hot/cold spots and ensuring consistent comfort.

Flash Streamer Technology

Advanced air purification system breaks down allergens, odors, and bacteria, providing cleaner, healthier indoor air quality.

Powerful Heating

Specialized heating operation maintains high efficiency even in extremely cold conditions down to -15°C outdoor temperature.

Quiet Operation

Special noise reduction technology ensures ultra-quiet operation as low as 19 dB(A), quieter than a whisper.

Eco-friendly R32 Refrigerant

Uses R32 refrigerant with lower global warming potential (GWP) than conventional refrigerants, reducing environmental impact.

Operating Modes Explained

Cool Mode

Standard cooling operation with temperature control from 18°C to 30°C

Heat Mode

Heating operation with temperature control from 16°C to 30°C

Dry Mode

Dehumidification without excessive cooling, ideal for humid conditions

Fan Mode

Air circulation only without cooling or heating

Auto Mode

Automatically selects cooling or heating based on room temperature

Night Mode

Quiet operation with gradual temperature adjustment for comfortable sleep

Troubleshooting

Problem Possible Cause Solution
Unit not starting Power issue, remote control batteries dead, circuit breaker tripped Check power supply, replace remote batteries, reset circuit breaker
Poor cooling/heating Dirty filters, blocked air vents, incorrect temperature setting Clean filters, clear obstructions, set appropriate temperature
Water leaking indoors Clogged drain pipe, improper installation slope Clear drain pipe, ensure proper drainage slope
Unusual noises Loose parts, debris in fan, ice formation Tighten components, clean unit, check for ice buildup
Foul odors Dirty filters, mold growth in drain pan Clean filters and drain pan, use air purification mode
Remote not working Dead batteries, signal obstruction, distance too far Replace batteries, ensure line of sight, stay within 7 meters

Error Codes

  • E0: Protection device activated - Wait 3 minutes and restart
  • E1: Indoor PCB error - Contact service center
  • E3: High pressure error - Check for blocked condenser
  • E5: Overload protection - Reduce load or wait for reset
  • E6: Communication error - Check wiring between units
  • E7: Outdoor fan motor error - Contact service center
  • F3: Discharge temperature error - Check refrigerant charge
  • H3: High pressure switch error - Check for restrictions
  • L4: Inverter compressor error - Contact service center
  • U0: Refrigerant shortage - Check for leaks and recharge

Manual Downloads

Current Model Manuals

FTXS25FV1B

2.5kW Inverter AC

FTXS35FV1B

3.5kW Inverter AC

FTXS50FV1B

5.0kW Inverter AC

FTXS60FV1B

6.0kW Inverter AC

Popular Previous Models

FTXS20FV1B

2.0kW Inverter AC

FTXS25GXV1B

2.5kW Premium AC

FTXS35JXV1B

3.5kW Smart AC

FTXS50KXV1B

5.0kW Wi-Fi AC

Note: For models not listed here, please visit the Daikin Support Website for complete documentation.