Daikin Split System Air Conditioner

User Manual & Installation Guide

Inverter Technology

Installation Guide

Tools Needed:

  • Adjustable wrench
  • Level
  • Screwdrivers (flat and Phillips)
  • Pipe cutter
  • Vacuum pump
  • Manifold gauge set
  • Torque wrench

Step-by-Step Installation

  1. Choose Installation Location: Select a location for indoor and outdoor units considering airflow, drainage, and accessibility for maintenance.
  2. Mount Indoor Unit: Install the indoor unit on a sturdy wall at least 2.2 meters above floor level, ensuring proper clearance from ceilings and walls.
  3. Install Outdoor Unit: Place outdoor unit on a solid, level surface with adequate ventilation and minimal vibration transmission.
  4. Connect Refrigerant Pipes: Connect copper pipes between indoor and outdoor units using proper brazing techniques and nitrogen purging.
  5. Electrical Connection: Connect to a properly grounded power supply according to local electrical codes. Use dedicated circuit.
  6. Vacuum and Charge: Evacuate the system using a vacuum pump, then charge with refrigerant according to manufacturer specifications.
  7. Test Run: Run the air conditioner through complete cooling and heating cycles to check for proper operation and leaks.
Warning: Installation must be performed by a qualified HVAC technician. Improper installation may cause injury, damage, or void warranty.

Specifications

Model Series FTXS Series
Type Wall Mounted Split System
Cooling Capacity 9,000 - 24,000 BTU/h
Heating Capacity 9,500 - 27,000 BTU/h
Noise Level (Indoor/Outdoor) 19 dB / 46 dB
Control Type Remote Control with LCD Display
Energy Rating A+++ (Most Efficient)
Power Requirements 220-240V, 50Hz, 1 Phase
Refrigerant R-32
Dimensions Indoor (HxWxD) 29.5 x 79.8 x 24.9 cm
Dimensions Outdoor (HxWxD) 55 x 79.8 x 28.9 cm
Weight Indoor/Outdoor 9 kg / 31 kg
Operating Temperature -15°C to 46°C

Warranty Information

  • Full Warranty: 5 years parts and labor
  • Compressor Warranty: 7 years on inverter compressor
  • Additional Coverage: Optional extended warranty available

For warranty service, contact Daikin Customer Service at 1-800-432-1342 or visit Daikin.com

Key Features

Inverter Technology

Daikin's advanced inverter technology adjusts compressor speed to maintain desired temperature, reducing energy consumption by up to 30% compared to conventional systems.

Coanda Airflow

Intelligent airflow control spreads cool or warm air evenly throughout the room by following the ceiling surface, preventing direct drafts on occupants.

Flash Streamer Technology

Advanced air purification system that breaks down allergens, odors, and airborne contaminants, providing cleaner, healthier indoor air.

Quiet Operation

Specially designed components and sound-dampening materials ensure whisper-quiet operation as low as 19 dB, quieter than a library.

Intelligent Eye

Motion sensor detects room occupancy and adjusts operation to save energy when the room is unoccupied, then resumes comfort settings when people return.

Powerful Operation

Quick cooling and heating capability reaches desired temperature rapidly, with powerful operation even in extreme outdoor conditions.

Operation Modes Explained

Cool Mode

Standard cooling operation with adjustable temperature and fan speed settings

Heat Mode

Efficient heating operation with defrost cycle for winter conditions

Dry Mode

Dehumidification function that removes excess moisture without overcooling

Fan Mode

Air circulation only, without cooling or heating, with multiple fan speeds

Auto Mode

Intelligent mode that automatically selects cooling or heating based on room temperature

Night Mode

Quiet operation with gradual temperature adjustment for comfortable sleep

Troubleshooting

Problem Possible Cause Solution
Unit won't start Power issue, remote control batteries dead, circuit breaker tripped Check power supply, replace remote batteries, reset circuit breaker
Poor cooling/heating Dirty filters, blocked airflow, refrigerant leak Clean filters, clear obstructions, contact service technician
Water leaking indoors Clogged drain pipe, improper installation slope Clear drain pipe, ensure proper drainage slope
Unusual noises Loose parts, debris in fan, ice buildup Tighten components, clear debris, check for proper operation
Frozen indoor unit Dirty filters, low refrigerant, fan motor issue Clean filters, contact technician for refrigerant check
Remote not working Dead batteries, signal obstruction, sensor issue Replace batteries, ensure line of sight, check sensor

Error Codes

  • E0: Protection device activated - Check for obstructions
  • E1: Indoor PCB issue - Contact service center
  • E3: High pressure error - Check outdoor unit ventilation
  • E5: Overload protection - Reduce load or wait for reset
  • E6: Communication error - Check wiring connections
  • F3: Discharge temperature error - Contact technician
  • H3: High pressure switch error - Check refrigerant charge
  • L5: Inverter compressor error - Contact service center

Manual Downloads

Current Model Manuals

FTXS25LVMA

2.5kW Split System

FTXS35LVMA

3.5kW Split System

FTXS50LVMA

5.0kW Split System

FTXS60LVMA

6.0kW Split System

Popular Previous Models

FTXS20LVMA

2.0kW Split System

FTXS71LVMA

7.1kW Split System

FTKG25LVMA

2.5kW Basic Model

FTKG35LVMA

3.5kW Basic Model

Note: For models not listed here, please visit the Daikin Support Website for complete documentation.