Dometic Caravan Air Conditioner

User Manual & Installation Guide

RV & Caravan Series

Installation Guide

Tools Needed:

  • Roof mounting kit
  • Sealant (RV approved)
  • Power drill with hole saw
  • Wire strippers/crimpers
  • Multimeter
  • Screwdrivers set
  • Wrench set

Step-by-Step Installation

  1. Roof Preparation: Select a flat, reinforced area on the caravan roof away from vents and antennas.
  2. Template Positioning: Use the provided template to mark cutting lines for the unit and wiring holes.
  3. Cut Opening: Carefully cut the roof opening using appropriate tools, ensuring clean edges.
  4. Apply Sealant: Apply RV-approved sealant around the opening to prevent water ingress.
  5. Mount Unit: Position the air conditioner unit and secure with mounting brackets and screws.
  6. Electrical Connection: Connect to 12V/24V DC system for control and 230V AC for compressor power.
  7. Ductwork Installation: Install and seal duct connections to ensure proper airflow distribution.
  8. Control Panel: Mount and wire the interior control panel according to wiring diagram.
  9. System Test: Test all functions including cooling, heating, and fan modes.
Warning: Installation must be performed by qualified personnel. Ensure proper roof reinforcement and sealing to prevent leaks and structural damage.

Specifications

Model Series PENGUIN II / Brisk II
Type Roof-mounted RV Air Conditioner
Cooling Capacity 13,500 BTU/h
Heating Capacity 1,600W (Optional heat pump)
Power Consumption (Cooling) 1,350W
Air Flow 320 m³/h
Noise Level 52-58 dB(A)
Control Type Digital Touch Control / Remote
Power Requirements 230V AC, 50Hz / 12V DC
Dimensions (LxWxH) 89 x 89 x 28 cm
Weight 34 kg
Refrigerant R410A
Operating Temperature -15°C to +50°C

Warranty Information

  • Standard Warranty: 2 years parts and labor
  • Compressor Warranty: 5 years
  • Extended Coverage: Optional 3-year extension available

For warranty service, contact Dometic Customer Service at 1-800-301-8118 or visit Dometic.com

Key Features

Low Profile Design

Streamlined roof-mounted design with minimal height for improved aerodynamics and reduced wind noise while driving.

Multi-Speed Fan

Three-speed fan control allows customized airflow from gentle circulation to maximum cooling power.

Heat Pump Option

Reverse cycle heating provides efficient warmth during cooler months without requiring additional heating systems.

Quiet Operation

Advanced compressor technology and insulated housing minimize operational noise for comfortable living spaces.

Smart Control System

Digital control panel with LCD display and optional remote control for convenient temperature management.

Energy Efficient

High EER (Energy Efficiency Ratio) rating ensures maximum cooling with minimal power consumption, ideal for off-grid use.

Operating Modes

Cooling Mode

Standard air conditioning with adjustable temperature settings from 16°C to 30°C

Heating Mode

Heat pump operation for energy-efficient heating (available on selected models)

Fan Only

Circulates air without cooling or heating, with three speed settings

Auto Mode

Automatically switches between cooling and heating to maintain set temperature

Dehumidify

Reduces humidity while maintaining comfortable temperature levels

Night Mode

Quieter operation with reduced fan speed for undisturbed sleep

Troubleshooting

Problem Possible Cause Solution
Unit not starting Power supply issue, blown fuse, low voltage Check power connections, replace fuse, verify battery voltage
Poor cooling performance Dirty filters, low refrigerant, blocked condenser Clean filters, check for leaks, clear condenser fins
Water leakage inside Clogged drain tube, improper installation angle Clear drain tube, ensure proper unit leveling
Unusual noises Loose components, debris in fan, worn bearings Tighten mounting hardware, clean fan blades, inspect motor
Fan running but no cooling Compressor issue, refrigerant leak, electrical fault Check compressor operation, look for leaks, test capacitors
Error code displayed System fault, sensor failure, communication error Refer to error code chart, check wiring connections

Error Codes

  • E1: Room temperature sensor fault - Check sensor connection
  • E2: Evaporator temperature sensor fault - Inspect sensor wiring
  • E3: High pressure protection - Clean condenser, check refrigerant
  • E4: Low pressure protection - Check for refrigerant leaks
  • E5: Communication error - Check control panel wiring
  • E6: Compressor overload - Allow system to cool, check voltage
  • E7: Fan motor fault - Inspect fan motor and blades
  • E8: Heating system fault - Check heating elements (if equipped)

Manual Downloads

Current Model Manuals

PENGUIN II 13500

13,500 BTU Low Profile

BRISK II 15000

15,000 BTU with Heat Pump

PENGUIN II 11000

11,000 BTU Compact

BRISK AIR 13500

13,500 BTU Standard

Popular Previous Models

PENGUIN 13500

13,500 BTU Classic

BRISK 15000

15,000 BTU Standard

BREEZE 11000

11,000 BTU Compact

PENGUIN 9500

9,500 BTU Small RV

Note: For models not listed here, please visit the Dometic Support Website for complete documentation.