Dometic Roof Air Conditioner

User Manual & Installation Guide

Roof Mounted RV AC Unit

Installation Guide

Tools Needed:

  • Power drill with hole saw
  • Socket wrench set
  • Roof sealant (self-leveling)
  • Measuring tape
  • Utility knife
  • Screwdrivers (flat and Phillips)
  • Wire strippers/crimpers

Step-by-Step Installation

  1. Prepare Installation Site: Select a location on the RV roof with adequate structural support and clear of obstructions.
  2. Cut Roof Opening: Using the provided template, mark and cut the roof opening according to manufacturer specifications.
  3. Install Roof Gasket: Apply self-leveling sealant to the roof gasket and position it around the cut opening.
  4. Mount AC Unit: Lift the air conditioner onto the roof and position it over the opening, aligning with mounting holes.
  5. Secure Unit: Secure the unit from inside the RV using the provided mounting brackets and hardware.
  6. Electrical Connection: Connect power wires according to wiring diagram, ensuring proper grounding and circuit protection.
  7. Install Interior Components: Mount the interior control panel and ductwork as specified in the manual.
  8. Test Operation: Test all functions including cooling, fan speeds, and thermostat operation.
Warning: Installation should be performed by qualified RV technicians. Improper installation may void warranty and cause roof damage or electrical hazards.

Specifications

Model Series PENGUIN II / Brisk II
Type Roof Mounted RV Air Conditioner
Cooling Capacity 13,500 BTU/h
Power Requirements 115V, 60Hz, 12.5A
Air Flow (High) 320 CFM
Control Type Digital Thermostat with Remote
Energy Efficiency Ratio 11.0 EER
Dimensions (LxWxH) 28.5 x 27.5 x 12.5 inches
Weight 75 lbs
Noise Level 58 dB (Low Speed)
Refrigerant R-410A
Ducted/Non-Ducted Both configurations available

Warranty Information

  • Limited Warranty: 2 years parts and labor
  • Compressor Warranty: 3 years on sealed system
  • Extended Coverage: Optional extended warranty available

For warranty service, contact Dometic Customer Service at 1-800-544-4881 or visit Dometic.com

Key Features

High Efficiency Compressor

Advanced rotary compressor technology provides maximum cooling performance with minimal power consumption, ideal for RV electrical systems.

Low Profile Design

Streamlined aerodynamic design reduces wind resistance and improves fuel efficiency while traveling.

Multi-Speed Fan

Three-speed fan operation allows for customized airflow and noise levels depending on cooling needs and preferences.

Heat Strip Option

Optional electric heat strip provides auxiliary heating capability for year-round comfort.

Easy-Access Service Panels

Removable service panels provide convenient access to filters, electrical components, and drainage system.

Condensate Management

Advanced drainage system prevents water accumulation and directs condensate away from the RV exterior.

Operating Modes

Cool Mode

Standard cooling operation with thermostat control for maintaining set temperature

Fan Only Mode

Circulates air without cooling, available in three speed settings

Economy Mode

Energy-saving operation that cycles compressor to maintain temperature efficiently

Dehumidify Mode

Reduces humidity while minimizing temperature drop for comfort in damp conditions

Heat Mode

Available with optional heat strip for supplemental heating (models with heat strip only)

Auto Mode

Automatically switches between cooling and fan operation to maintain set temperature

Troubleshooting

Problem Possible Cause Solution
AC unit won't start Power issue, thermostat setting, circuit breaker Check power supply, verify thermostat settings, reset circuit breaker
Poor cooling performance Dirty filters, low refrigerant, restricted airflow Clean/replace filters, check for obstructions, verify refrigerant charge
Water leaking inside Clogged drain, improper installation, condensate overflow Clear drain tube, check unit leveling, ensure proper drainage
Unusual noises Loose components, debris in fan, bearing wear Tighten mounting hardware, clear debris from fan, check motor bearings
Fan runs but no cooling Compressor issue, refrigerant leak, electrical fault Check compressor operation, look for refrigerant leaks, verify electrical connections
Unit cycles on/off frequently Dirty coils, thermostat location, over/undersized unit Clean evaporator coils, relocate thermostat if in direct sunlight

Error Codes

  • E1: Room temperature sensor fault - Check sensor connection
  • E2: Evaporator temperature sensor fault - Check sensor and wiring
  • E3: High pressure fault - Check condenser airflow and cleanliness
  • E4: Low pressure fault - Check refrigerant charge and for leaks
  • E5: Compressor overload - Check electrical supply and compressor
  • E6: Communication error - Check control board connections

Manual Downloads

Current Model Manuals

Brisk II 13500

13,500 BTU Roof AC

Penguin II 15000

15,000 BTU Low Profile

Brisk II 11000

11,000 BTU Roof AC

Penguin II w/Heat

13,500 BTU with Heat Strip

Popular Previous Models

Brisk Air 13500

13,500 BTU Standard

Penguin 11000

11,000 BTU Low Profile

Brisk Air 15000

15,000 BTU High Capacity

Penguin w/Duct

13,500 BTU Ducted System

Note: For models not listed here, please visit the Dometic Support Website for complete documentation.