Fujitsu Ducted Air Conditioning System

User Manual & Installation Guide

Ducted Series

Installation Guide

Tools Needed:

  • Refrigeration gauge manifold
  • Vacuum pump
  • Tube bender and cutter
  • Electrical multimeter
  • Insulation materials
  • Ductwork tools

Step-by-Step Installation

  1. Site Selection: Choose appropriate location for outdoor unit with proper clearance and indoor unit placement in ceiling space.
  2. Ductwork Installation: Install insulated ductwork according to calculated airflow requirements and room layouts.
  3. Refrigerant Piping: Connect copper piping between indoor and outdoor units, ensuring proper insulation and slope.
  4. Electrical Connections: Connect power supply to outdoor unit and control wiring between indoor and outdoor units.
  5. Drainage System: Install condensate drain line with proper slope and trap to ensure effective water removal.
  6. Vacuum and Charge: Evacuate system to remove moisture and air, then charge with specified refrigerant amount.
  7. System Testing: Test all functions including cooling, heating, fan speeds, and thermostat operation.
Warning: Installation must be performed by licensed HVAC technicians to ensure safety, proper operation, and maintain warranty coverage.

Specifications

Model Series ARU36RFL / AOU36RFL
System Type Ducted Split System
Cooling Capacity 10.5 kW (3.6 tons)
Heating Capacity 11.2 kW
Power Supply 230V, 50Hz, 1 Phase
Refrigerant Type R410A
Energy Rating 5 Star (Highest Efficiency)
Indoor Unit Noise 28-38 dB(A)
Outdoor Unit Noise 52 dB(A)
Operating Range (Cooling) -10°C to 46°C Outdoor
Operating Range (Heating) -15°C to 24°C Outdoor
Dimensions (Outdoor Unit) 89 x 80 x 32 cm
Weight (Outdoor Unit) 68 kg

Warranty Information

  • Full Warranty: 5 years parts and labor
  • Compressor Warranty: 7 years on inverter compressor
  • Extended Coverage: Optional 10-year warranty available

For warranty service, contact Fujitsu Customer Service at 1-800-228-4236 or visit Fujitsu-General.com

Key Features

Inverter Technology

Advanced DC inverter compressor adjusts speed to match cooling/heating demand, providing precise temperature control and significant energy savings.

Multi-Zone Control

Capability to control up to 8 different zones independently, allowing customized temperature settings for each room or area.

Quiet Operation

Specially designed fan blades and sound-dampening materials ensure whisper-quiet operation for both indoor and outdoor units.

Advanced Filtration

Multi-stage filtration system including plasma and electrostatic filters to remove dust, pollen, and airborne contaminants.

Wi-Fi Connectivity

Built-in Wi-Fi allows remote control via smartphone app, scheduling, energy monitoring, and integration with smart home systems.

Low Ambient Operation

Specialized technology allows efficient heating operation even in extremely cold conditions down to -15°C outdoor temperature.

Operation Modes

Auto Mode

System automatically selects cooling or heating based on room temperature

Cooling Mode

Standard air conditioning operation with adjustable temperature and fan speed

Heating Mode

Reverse cycle heating with defrost function for cold weather operation

Dry Mode

Dehumidification function that reduces humidity without significant cooling

Fan Only Mode

Circulates air without cooling or heating, with adjustable fan speeds

Sleep Mode

Gradually adjusts temperature for optimal sleeping conditions and energy savings

Troubleshooting

Problem Possible Cause Solution
System not starting Power issue, thermostat setting, safety lockout Check circuit breaker, verify thermostat settings, wait for lockout reset
Poor cooling/heating Dirty filters, low refrigerant, blocked airflow Clean filters, check refrigerant charge, clear obstructions
Water leakage Clogged drain line, improper slope, frozen coil Clear drain line, ensure proper slope, check for ice formation
Unusual noises Loose parts, debris in fan, vibration Tighten components, clear debris, check mounting
Frequent cycling Dirty filters, thermostat location, oversized unit Clean filters, relocate thermostat, consult technician
Error code display System fault, sensor failure, communication error Note error code, power cycle system, contact technician

Common Error Codes

  • E0: Room temperature sensor fault - Check sensor connection
  • E1: Indoor unit PCB fault - Power cycle system
  • E3: High pressure protection - Check for blockage, wait for reset
  • E4: Low pressure protection - Check refrigerant charge
  • E5: Compressor overload - Allow system to cool down
  • E6: Communication error - Check wiring between units
  • E7: Outdoor fan motor fault - Check fan operation
  • E9: Water level alarm - Check drain system

Manual Downloads

Current Ducted Series

ARU36RFL

10.5kW Ducted Inverter

ARU48RFL

13.5kW Ducted Inverter

ARU60RFL

17.0kW Ducted Inverter

ARU72RFL

20.0kW Ducted Inverter

Popular Previous Models

ARU30RFL

8.5kW Ducted System

ARU42RFL

12.0kW Ducted System

ARU54RFL

15.0kW Ducted System

ARU66RFL

18.5kW Ducted System

Accessory Manuals

Wired Controller

Standard Wall Controller

Wireless Kit

Wi-Fi Adapter Manual

Zone Controller

Multi-Zone Control System

Installation Guide