Fujitsu Split Type Air Conditioner

User Manual & Installation Guide

Wall Mounted Series

Installation Guide

Tools Needed:

  • Vacuum pump with gauge manifold
  • Refrigerant charging scale
  • Pipe cutter and flaring tool
  • Torque wrench
  • Multimeter
  • Level
  • Drill with hole saw

Step-by-Step Installation

  1. Select Installation Location: Choose a location with proper clearance (minimum 30cm from ceiling, 15cm from walls) and away from heat sources.
  2. Mount Indoor Unit Bracket: Securely mount the bracket to a solid wall using appropriate anchors and ensure it is perfectly level.
  3. Drill Wall Hole: Drill a 65mm hole through the wall with a slight downward slope to the outside for drainage.
  4. Connect Refrigerant Pipes: Connect copper pipes between indoor and outdoor units, ensuring proper insulation and avoiding sharp bends.
  5. Connect Drain Hose: Route the drain hose with a continuous downward slope to ensure proper water drainage.
  6. Electrical Connection: Connect to a dedicated circuit with proper grounding according to local electrical codes.
  7. Vacuum and Charge: Evacuate the system to 500 microns and charge with the specified amount of refrigerant.
  8. Test Operation: Test all functions including cooling, heating, fan speeds, and remote control operation.
Warning: Installation must be performed by a licensed HVAC technician. Improper installation may cause injury, damage, or void warranty.

Specifications

Model Series ASU24RLF / AOU24RLF
Type Split Type Air Conditioner
Color White / Silver
Cooling Capacity 24,000 BTU/h (7.0 kW)
Heating Capacity 26,000 BTU/h (7.6 kW)
Noise Level (Indoor) 19 dB - 38 dB
Control Type Wireless Remote with LCD Display
Energy Rating A+++ (Cooling) / A++ (Heating)
Power Requirements 220-240V, 50Hz, 1Ph
Refrigerant R32 (850g)
Dimensions Indoor (HxWxD) 29.5 x 79.8 x 22.4 cm
Dimensions Outdoor (HxWxD) 55.0 x 79.0 x 28.5 cm
Weight (Indoor/Outdoor) 9.5 kg / 34.0 kg
Operating Temperature -15°C to 46°C (Cooling) / -15°C to 24°C (Heating)

Warranty Information

  • Full Warranty: 5 years on compressor and parts
  • Extended Warranty: Optional 10-year compressor warranty available
  • Labor Coverage: 1 year installation labor

For warranty service, contact Fujitsu Customer Service at 1-800-223-3726 or visit Fujitsu-General.com

Key Features

Inverter Technology

Advanced DC inverter compressor adjusts cooling/heating capacity to match room conditions, providing consistent comfort while reducing energy consumption by up to 30%.

3D Airflow

Vertical and horizontal louvers operate independently to distribute air evenly throughout the room, eliminating hot/cold spots and ensuring uniform comfort.

Plasma Quad Filter

Four-stage filtration system removes dust, pollen, odors, and bacteria while deactivating viruses and mold spores for cleaner, healthier indoor air.

Wi-Fi Control

Built-in Wi-Fi allows remote control via smartphone app, enabling scheduling, energy monitoring, and control from anywhere with internet access.

Eco Mode

Intelligent energy-saving mode optimizes operation to maintain comfort while minimizing power consumption during extended use.

Quiet Operation

Specialized fan design and sound-dampening materials provide ultra-quiet operation as low as 19 dB, quieter than a whisper.

Operating Modes Explained

Cool Mode

Standard cooling operation with adjustable temperature and fan speed settings

Heat Mode

Heating operation with automatic defrost cycle for winter use

Dry Mode

Dehumidification function that removes excess moisture without overcooling

Fan Mode

Air circulation only without cooling or heating

Auto Mode

Automatically selects cooling or heating based on room temperature

Sleep Mode

Gradually adjusts temperature and reduces fan speed for comfortable sleeping

Troubleshooting

Problem Possible Cause Solution
Unit not turning on Power failure, circuit breaker tripped, remote battery dead Check power supply, reset breaker, replace remote batteries
Poor cooling/heating Dirty filters, blocked airflow, refrigerant leak Clean filters, clear obstructions, contact technician for leak check
Water dripping indoors Clogged drain pipe, improper installation slope Clear drain pipe, ensure proper downward slope
Unusual noises Loose parts, debris in fan, ice buildup Tighten mounting, clear debris, check for proper operation
Remote not working Batteries dead, signal blocked, sensor issue Replace batteries, ensure line of sight, check sensor window
Unit turns on/off frequently Thermostat issue, dirty filters, incorrect sizing Clean filters, check thermostat setting, verify proper capacity

Error Codes

  • E0: Protection device activated - Wait 3 minutes and restart
  • E1: Indoor PCB issue - Contact service center
  • E2: Communication error - Check wiring between units
  • E3: Outdoor fan motor issue - Contact technician
  • E4: High pressure protection - Clean outdoor coil, check fan
  • E5: Low pressure protection - Check for refrigerant leak
  • E6: Compressor overload - Wait 30 minutes and restart
  • E7: Temperature sensor error - Contact service center

Manual Downloads

Current Model Manuals

ASU24RLF

24,000 BTU Wall Mounted

ASU18RLF

18,000 BTU Wall Mounted

ASU12RLF

12,000 BTU Wall Mounted

ASU09RLF

9,000 BTU Wall Mounted

Popular Previous Models

ASU24RLA

24,000 BTU Standard Model

ASU18RLA

18,000 BTU Standard Model

ASU12RLA

12,000 BTU Standard Model

ASU09RLA

9,000 BTU Standard Model

Note: For models not listed here, please visit the Fujitsu Support Website for complete documentation.