LG Air Conditioning Installation Manual

User Manual & Installation Guide

Wall Mounted Split System

Installation Guide

Tools Needed:

  • Vacuum pump with manifold gauge
  • Torque wrench
  • Flaring tool set
  • Pipe cutter
  • Level
  • Drill with core bit
  • Refrigerant scale

Step-by-Step Installation

  1. Select Installation Location: Choose a location with proper clearances (minimum 15cm from ceiling, 30cm from walls) and adequate structural support.
  2. Mount Indoor Unit Bracket: Securely mount the wall bracket using appropriate anchors for wall type (concrete, brick, or drywall).
  3. Drill Wall Hole: Drill a 70mm hole through the wall with a slight downward slope (indoor to outdoor) for drainage.
  4. Connect Refrigerant Pipes: Connect copper pipes between indoor and outdoor units using flare connections. Ensure proper insulation on pipes.
  5. Connect Drain Hose: Install drain hose with proper slope (minimum 1/100 gradient) and route to appropriate drainage point.
  6. Electrical Connection: Connect power cables according to local electrical codes. Ensure proper grounding and circuit protection.
  7. Vacuum and Charge: Evacuate system to 500 microns minimum, then charge with specified amount of refrigerant (R32/R410A).
  8. Test Operation: Test all functions including cooling, heating, fan speeds, and remote control operation.
Warning: Installation must be performed by certified HVAC technicians only. Improper installation may cause injury, damage, or void warranty.

Specifications

Model Series ARNU12GFL4
Type Split System Air Conditioner
Cooling Capacity 12,000 BTU/h (3.5 kW)
Heating Capacity 13,500 BTU/h (4.0 kW)
Energy Efficiency Ratio (EER) 12.5
Seasonal Energy Efficiency Ratio (SEER) 22
Refrigerant Type R32 (Eco-friendly)
Power Requirements 220-240V, 50Hz, 1 Phase
Power Consumption (Cooling) 960W
Indoor Unit Dimensions (HxWxD) 29.5 x 79.8 x 20.9 cm
Outdoor Unit Dimensions (HxWxD) 54.0 x 79.0 x 29.0 cm
Noise Level (Indoor/Outdoor) 19 dB / 50 dB
Operating Temperature Range -15°C to 46°C (Cooling: 18°C to 46°C)

Warranty Information

  • Full Warranty: 2 years parts and labor
  • Compressor Warranty: 5 years on inverter compressor
  • Extended Warranty: Optional 5-year extended warranty available

For warranty service, contact LG Customer Service at 1-800-243-0000 or visit LG.com

Key Features

Dual Inverter Compressor

LG's advanced Dual Inverter technology provides precise temperature control, faster cooling/heating, and up to 70% energy savings compared to conventional compressors.

4-Way Air Swing

Automatically adjusts vertical and horizontal louvers to distribute air evenly throughout the room, eliminating hot/cold spots.

Plasma Air Purification

Advanced plasma technology removes up to 99.9% of airborne contaminants including bacteria, viruses, allergens, and odors.

SmartThinQ Technology

Wi-Fi enabled for remote control via smartphone app, allowing scheduling, energy monitoring, and voice control compatibility.

Auto Clean Function

Automatically dries the indoor unit's heat exchanger to prevent mold and bacteria growth, maintaining air quality and unit efficiency.

Low Ambient Operation

Specialized technology allows heating operation even in extremely cold temperatures down to -15°C.

Operating Modes

Cool Mode

Standard cooling operation with adjustable temperature (18°C-30°C) and fan speeds

Heat Mode

Heating operation with rapid warm-up feature and anti-cold draft technology

Dry Mode

Dehumidification without excessive cooling, ideal for humid conditions

Fan Mode

Air circulation only with multiple fan speed options

Auto Mode

Intelligent mode that automatically selects cooling or heating based on room temperature

Energy Saving

Optimizes operation to minimize energy consumption while maintaining comfort

Troubleshooting

Problem Possible Cause Solution
Unit not turning on Power outage, circuit breaker tripped, remote control batteries dead Check power supply, reset circuit breaker, replace remote batteries
Poor cooling/heating Dirty filters, blocked airflow, refrigerant leak, outdoor unit obstructed Clean filters, clear obstructions, check refrigerant charge
Water leaking indoors Clogged drain pipe, improper installation slope, frozen evaporator Clear drain line, check installation angle, defrost unit
Unusual noises Loose parts, debris in fan, vibration from mounting Tighten all fasteners, clear debris, check mounting stability
Foul odors Dirty filters, mold growth in drain pan, stagnant water Clean filters and drain pan, run fan mode to dry unit
Remote not working Batteries dead, signal blocked, remote sensor issue Replace batteries, ensure line of sight, check sensor window

Error Codes

  • CH 00: Communication error between indoor and outdoor units
  • CH 01: Indoor unit PCB malfunction
  • CH 02: Outdoor unit PCB malfunction
  • CH 03: Compressor drive error
  • CH 04: DC fan motor error
  • CH 05: Room temperature sensor error
  • CH 06: Pipe temperature sensor error
  • CH 07: Outdoor temperature sensor error
  • CH 08: Refrigerant pressure error
  • CH 09: Drain pump error

Manual Downloads

Current Model Manuals

ARNU12GFL4

12K BTU Wall Mounted Split

ARNU18GFL4

18K BTU Wall Mounted Split

ARNU24GFL4

24K BTU Wall Mounted Split

ARNU09GFL4

9K BTU Wall Mounted Split

Popular Previous Models

AS09HQ4N

9K BTU Standard Split

AS12HQ4N

12K BTU Standard Split

AS18HQ4N

18K BTU Standard Split

AS24HQ4N

24K BTU Standard Split

Note: For models not listed here, please visit the LG Support Website for complete documentation.