Installation Guide
Tools Needed:
- Refrigeration manifold gauge set
- Vacuum pump
- Tube cutter and bender
- Torque wrench
- Multimeter
- Leak detector
- Insulation materials
Step-by-Step Installation
- Site Selection: Choose appropriate location for outdoor unit with proper clearance (minimum 30cm from walls). Ensure indoor unit location allows for proper ductwork routing.
- Mounting: Install outdoor unit on level concrete pad or mounting brackets. Secure indoor unit in designated space with proper support.
- Ductwork Installation: Install insulated ductwork according to layout plan. Ensure proper sealing at all joints to prevent air leakage.
- Refrigerant Piping: Connect refrigerant lines between indoor and outdoor units. Use nitrogen purge while brazing to prevent oxidation.
- Electrical Connection: Connect power supply according to local electrical codes. Install dedicated circuit with proper grounding.
- Control Wiring: Connect thermostat and zone control wiring. Ensure proper communication between all system components.
- System Evacuation: Evacuate system to 500 microns or less using vacuum pump. Hold vacuum for minimum 30 minutes.
- Charging: Charge system with specified refrigerant type and quantity. Check for leaks using electronic leak detector.
- Commissioning: Start system and verify all functions. Check temperature differentials and airflow at all registers.
Specifications
| Model Series | ARTCOOL Mirror Series |
| Type | Ducted Multi-Zone Inverter System |
| Cooling Capacity | 48,000 BTU/h (14kW) |
| Heating Capacity | 51,000 BTU/h (15kW) |
| Energy Efficiency Ratio (EER) | 12.5 |
| Heating Seasonal Performance (HSPF) | 9.5 |
| Refrigerant Type | R-410A |
| Power Requirements | 208-230V, 60Hz, 3-Phase |
| Maximum Zones | 8 Zones |
| Indoor Unit Noise Level | 19-38 dB(A) |
| Outdoor Unit Dimensions | 115 x 90 x 45 cm |
| Indoor Unit Dimensions | 140 x 60 x 30 cm |
| Maximum Pipe Length | 50 meters |
| Maximum Height Difference | 30 meters |
Warranty Information
- Compressor Warranty: 10 years parts
- Parts Warranty: 5 years parts
- Labor Warranty: 1 year labor
- Extended Coverage: Optional extended warranty available
For warranty service, contact LG HVAC Support at 1-800-243-0000 or visit LG.com/hvac
Key Features
Dual Inverter Compressor
LG's advanced dual inverter compressor provides precise temperature control, faster cooling/heating, and up to 70% energy savings compared to conventional systems.
Multi-Zone Control
Independently control up to 8 different zones with individual temperature settings. Perfect for homes with varying cooling/heating needs in different rooms.
Plasma Air Purification
Advanced plasma air purification system removes up to 99.9% of airborne contaminants including viruses, bacteria, allergens, and odors.
SmartThinQ Technology
Wi-Fi enabled for remote control via smartphone app. Monitor energy usage, adjust temperatures, and receive maintenance alerts from anywhere.
Auto Clean Function
Automatically dries the indoor unit's heat exchanger after use to prevent mold and bacteria growth, ensuring cleaner air and better efficiency.
Quiet Operation
Specialized noise reduction technology ensures whisper-quiet operation as low as 19dB, quieter than a library.
Operating Modes
Cooling Mode
Standard air conditioning operation with precise temperature control and humidity removal
Heating Mode
Efficient heat pump operation for winter heating with defrost cycle for cold weather
Dry Mode
Dehumidification without significant cooling, perfect for humid days
Fan Mode
Air circulation without cooling or heating, with multiple fan speed options
Auto Mode
Intelligent mode that automatically switches between cooling and heating based on room temperature
Energy Saving
Optimizes operation to minimize energy consumption while maintaining comfort
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| System not starting | Power issue, thermostat setting, safety lockout | Check circuit breaker, verify thermostat settings, wait 3 minutes for compressor protection |
| Poor cooling/heating | Dirty filters, low refrigerant, blocked airflow | Clean filters, check refrigerant charge, clear obstructions around units |
| Unusual noises | Loose parts, debris in fan, refrigerant issues | Tighten mounting hardware, clear debris from fans, check refrigerant piping |
| Water leakage | Clogged drain line, improper slope, frozen coil | Clear drain line, ensure proper drainage slope, check for ice on coils |
| Frozen coils | Low airflow, low refrigerant, dirty filters | Check filters, verify fan operation, check refrigerant charge |
| Zone not working | Damper issue, zone controller fault, wiring problem | Check damper operation, verify zone controller settings, check wiring connections |
Error Codes
- CH 01: Indoor unit communication error - Check wiring between indoor and outdoor units
- CH 02: Outdoor unit communication error - Check power to outdoor unit
- CH 03: Compressor overload - Wait 30 minutes and restart
- CH 04: High pressure fault - Check for restricted airflow or overcharge
- CH 05: Low pressure fault - Check for refrigerant leak or restriction
- CH 06: Inverter module fault - Contact service technician
- CH 07: Temperature sensor fault - Check sensor connections and resistance
- CH 08: Drain pump fault - Check drain pump and float switch CH 09: EEPROM error - Contact service technician
Manual Downloads
Current Model Manuals
ARTCOOL MIRROR
48k BTU Multi-Zone System
ARTCOOL GALLERY
36k BTU Ducted System
DUALCOOL INVERTER
60k BTU Multi-Zone System
STANDARD DUCTED
24k BTU Single Zone
Popular Previous Models
MULTI V S
54k BTU VRF System
ARTCOOL PREMIUM
42k BTU Multi-Zone
DUCTED INVERTER
30k BTU Single Zone
MULTI F