LG Ducted Air Conditioner

User Manual & Installation Guide

Multi-Zone System

Installation Guide

Tools Needed:

  • Refrigeration manifold gauge set
  • Vacuum pump
  • Tube cutter and bender
  • Torque wrench
  • Multimeter
  • Leak detector
  • Insulation materials

Step-by-Step Installation

  1. Site Selection: Choose appropriate location for outdoor unit with proper clearance (minimum 30cm from walls). Ensure indoor unit location allows for proper ductwork routing.
  2. Mounting: Install outdoor unit on level concrete pad or mounting brackets. Secure indoor unit in designated space with proper support.
  3. Ductwork Installation: Install insulated ductwork according to layout plan. Ensure proper sealing at all joints to prevent air leakage.
  4. Refrigerant Piping: Connect refrigerant lines between indoor and outdoor units. Use nitrogen purge while brazing to prevent oxidation.
  5. Electrical Connection: Connect power supply according to local electrical codes. Install dedicated circuit with proper grounding.
  6. Control Wiring: Connect thermostat and zone control wiring. Ensure proper communication between all system components.
  7. System Evacuation: Evacuate system to 500 microns or less using vacuum pump. Hold vacuum for minimum 30 minutes.
  8. Charging: Charge system with specified refrigerant type and quantity. Check for leaks using electronic leak detector.
  9. Commissioning: Start system and verify all functions. Check temperature differentials and airflow at all registers.
Warning: Installation must be performed by licensed HVAC technicians only. Improper installation may void warranty and create safety hazards.

Specifications

Model Series ARTCOOL Mirror Series
Type Ducted Multi-Zone Inverter System
Cooling Capacity 48,000 BTU/h (14kW)
Heating Capacity 51,000 BTU/h (15kW)
Energy Efficiency Ratio (EER) 12.5
Heating Seasonal Performance (HSPF) 9.5
Refrigerant Type R-410A
Power Requirements 208-230V, 60Hz, 3-Phase
Maximum Zones 8 Zones
Indoor Unit Noise Level 19-38 dB(A)
Outdoor Unit Dimensions 115 x 90 x 45 cm
Indoor Unit Dimensions 140 x 60 x 30 cm
Maximum Pipe Length 50 meters
Maximum Height Difference 30 meters

Warranty Information

  • Compressor Warranty: 10 years parts
  • Parts Warranty: 5 years parts
  • Labor Warranty: 1 year labor
  • Extended Coverage: Optional extended warranty available

For warranty service, contact LG HVAC Support at 1-800-243-0000 or visit LG.com/hvac

Key Features

Dual Inverter Compressor

LG's advanced dual inverter compressor provides precise temperature control, faster cooling/heating, and up to 70% energy savings compared to conventional systems.

Multi-Zone Control

Independently control up to 8 different zones with individual temperature settings. Perfect for homes with varying cooling/heating needs in different rooms.

Plasma Air Purification

Advanced plasma air purification system removes up to 99.9% of airborne contaminants including viruses, bacteria, allergens, and odors.

SmartThinQ Technology

Wi-Fi enabled for remote control via smartphone app. Monitor energy usage, adjust temperatures, and receive maintenance alerts from anywhere.

Auto Clean Function

Automatically dries the indoor unit's heat exchanger after use to prevent mold and bacteria growth, ensuring cleaner air and better efficiency.

Quiet Operation

Specialized noise reduction technology ensures whisper-quiet operation as low as 19dB, quieter than a library.

Operating Modes

Cooling Mode

Standard air conditioning operation with precise temperature control and humidity removal

Heating Mode

Efficient heat pump operation for winter heating with defrost cycle for cold weather

Dry Mode

Dehumidification without significant cooling, perfect for humid days

Fan Mode

Air circulation without cooling or heating, with multiple fan speed options

Auto Mode

Intelligent mode that automatically switches between cooling and heating based on room temperature

Energy Saving

Optimizes operation to minimize energy consumption while maintaining comfort

Troubleshooting

Problem Possible Cause Solution
System not starting Power issue, thermostat setting, safety lockout Check circuit breaker, verify thermostat settings, wait 3 minutes for compressor protection
Poor cooling/heating Dirty filters, low refrigerant, blocked airflow Clean filters, check refrigerant charge, clear obstructions around units
Unusual noises Loose parts, debris in fan, refrigerant issues Tighten mounting hardware, clear debris from fans, check refrigerant piping
Water leakage Clogged drain line, improper slope, frozen coil Clear drain line, ensure proper drainage slope, check for ice on coils
Frozen coils Low airflow, low refrigerant, dirty filters Check filters, verify fan operation, check refrigerant charge
Zone not working Damper issue, zone controller fault, wiring problem Check damper operation, verify zone controller settings, check wiring connections

Error Codes

  • CH 01: Indoor unit communication error - Check wiring between indoor and outdoor units
  • CH 02: Outdoor unit communication error - Check power to outdoor unit
  • CH 03: Compressor overload - Wait 30 minutes and restart
  • CH 04: High pressure fault - Check for restricted airflow or overcharge
  • CH 05: Low pressure fault - Check for refrigerant leak or restriction
  • CH 06: Inverter module fault - Contact service technician
  • CH 07: Temperature sensor fault - Check sensor connections and resistance
  • CH 08: Drain pump fault - Check drain pump and float switch
  • CH 09: EEPROM error - Contact service technician

Manual Downloads

Current Model Manuals

ARTCOOL MIRROR

48k BTU Multi-Zone System

ARTCOOL GALLERY

36k BTU Ducted System

DUALCOOL INVERTER

60k BTU Multi-Zone System

STANDARD DUCTED

24k BTU Single Zone

Popular Previous Models

MULTI V S

54k BTU VRF System

ARTCOOL PREMIUM

42k BTU Multi-Zone

DUCTED INVERTER

30k BTU Single Zone

MULTI F

48k BTU Ceiling Cassette

Note: For models not listed here, please visit the LG HVAC Support Website for complete documentation.