Mirage Split Air Conditioner

User Manual & Installation Guide

12000 BTU Capacity

Installation Guide

Tools Needed:

  • Drill with hole saw attachment
  • Vacuum pump
  • Manifold gauge set
  • Torque wrench
  • Level
  • Screwdrivers (flat and Phillips)
  • Pipe cutter
  • Flaring tool

Step-by-Step Installation

  1. Choose Installation Location: Select a location for indoor and outdoor units with proper clearance and structural support.
  2. Mount Indoor Unit: Install mounting plate on wall, ensuring it's level. Hang indoor unit on plate.
  3. Install Outdoor Unit: Place outdoor unit on stable, level surface with proper vibration isolation pads.
  4. Create Wall Opening: Drill hole through wall for refrigerant piping, drain hose, and electrical wiring.
  5. Connect Refrigerant Lines: Connect copper pipes between indoor and outdoor units using flare connections.
  6. Connect Drain Hose: Route drain hose with proper downward slope to ensure proper drainage.
  7. Electrical Connection: Connect to properly rated electrical circuit with dedicated breaker. Follow local electrical codes.
  8. Vacuum and Charge: Evacuate system with vacuum pump and charge with specified refrigerant amount.
  9. Test Run: Test all functions including cooling, heating, fan modes, and remote control operation.
Warning: Installation must be performed by certified HVAC technicians only. Improper installation can cause equipment damage, void warranty, and create safety hazards.

Specifications

Model Series MSP-12HRN1
Type Split System Air Conditioner
Color White / Silver
Cooling Capacity 12000 BTU/h
Heating Capacity 13000 BTU/h
Power Supply 220-240V, 50Hz, 1 Phase
Energy Rating A++ (Cooling) / A+ (Heating)
Refrigerant R32 (ECO Friendly)
Noise Level (Indoor/Outdoor) 19 dB / 50 dB
Dimensions Indoor (HxWxD) 29 x 80 x 21 cm
Dimensions Outdoor (HxWxD) 55 x 78 x 29 cm
Weight (Indoor/Outdoor) 9 kg / 28 kg
Air Flow (Indoor) 12 m³/min

Warranty Information

  • Full Warranty: 2 years parts and labor
  • Compressor Warranty: 5 years on rotary compressor
  • Extended Warranty: Optional 5-year extended warranty available

For warranty service, contact Mirage Customer Service at 1-800-555-MIRAGE or visit MirageAC.com

Key Features

Inverter Technology

Advanced DC inverter compressor adjusts cooling/heating capacity to maintain precise temperature control while reducing energy consumption by up to 40%.

Wi-Fi Smart Control

Connect to home Wi-Fi network for remote control via smartphone app. Schedule operations, monitor energy usage, and receive maintenance alerts.

4D Auto Swing

Multi-directional air flow system distributes air evenly throughout the room, eliminating hot/cold spots and ensuring consistent comfort.

Self-Cleaning Function

Automatically cleans indoor unit heat exchanger to prevent mold and bacteria growth, ensuring healthier air quality and maintaining efficiency.

Eco Mode

Intelligent energy-saving mode optimizes operation to reduce power consumption while maintaining comfort levels.

Quiet Operation

Specialized noise reduction technology ensures ultra-quiet operation as low as 19 dB, quieter than a whisper.

Operating Modes

Cool Mode

Standard cooling operation with adjustable temperature and fan speed settings

Heat Mode

Heating operation with efficient heat pump technology for winter comfort

Dry Mode

Dehumidification function reduces humidity without overcooling the room

Fan Mode

Circulates air without cooling or heating, with multiple fan speed options

Auto Mode

Intelligent mode automatically selects cooling or heating based on room temperature

Sleep Mode

Gradually adjusts temperature and reduces fan speed for undisturbed sleep

Troubleshooting

Problem Possible Cause Solution
Unit not turning on Power outage, circuit breaker tripped, remote control batteries dead Check power supply, reset breaker, replace remote batteries
Poor cooling/heating Dirty filters, blocked airflow, refrigerant leak, outdoor unit obstructed Clean filters, clear obstructions, check for leaks, clear outdoor unit area
Water dripping indoors Clogged drain pipe, improper installation slope, dirty filters Clear drain pipe, ensure proper slope, clean filters
Unusual noises Loose parts, debris in fan, improper installation Tighten components, clear debris, check installation
Foul odor Dirty filters, mold growth in indoor unit Clean filters, run self-cleaning cycle, professional cleaning if needed
Remote not working Dead batteries, signal obstruction, remote sensor issue Replace batteries, ensure line of sight, check sensor window

Error Codes

  • E1: Room temperature sensor failure - Check sensor connection
  • E2: Pipe temperature sensor failure - Check sensor connection
  • E3: Communication error - Check wiring between indoor/outdoor units
  • E4: High pressure protection - Check for blocked condenser, dirty filters
  • E5: Low pressure protection - Check for refrigerant leak
  • E6: Compressor overload - Allow unit to cool down, check voltage
  • E7: Fan motor error - Check fan motor and connections
  • E8: Water full protection - Check drain system

Manual Downloads

Current Model Manuals

MSP-12HRN1

12000 BTU Inverter Split AC

MSP-18HRN1

18000 BTU Inverter Split AC

MSP-24HRN1

24000 BTU Inverter Split AC

MSP-09HRN1

9000 BTU Inverter Split AC

Popular Previous Models

MSA-12HSN1

12000 BTU Standard Split AC

MSA-18HSN1

18000 BTU Standard Split AC

MSP-12HRW1

12000 BTU Wi-Fi Split AC

MSA-24HSN1

24000 BTU Standard Split AC

Note: For models not listed here, please visit the Mirage Support Website for complete documentation.