Installation Guide
Tools Needed:
- Drill with hole saw attachment
- Vacuum pump
- Manifold gauge set
- Torque wrench
- Level
- Screwdrivers (flat and Phillips)
- Pipe cutter
- Flaring tool
Step-by-Step Installation
- Choose Installation Location: Select a location for indoor and outdoor units with proper clearance and structural support.
- Mount Indoor Unit: Install mounting plate on wall, ensuring it's level. Hang indoor unit on plate.
- Install Outdoor Unit: Place outdoor unit on stable, level surface with proper vibration isolation pads.
- Create Wall Opening: Drill hole through wall for refrigerant piping, drain hose, and electrical wiring.
- Connect Refrigerant Lines: Connect copper pipes between indoor and outdoor units using flare connections.
- Connect Drain Hose: Route drain hose with proper downward slope to ensure proper drainage.
- Electrical Connection: Connect to properly rated electrical circuit with dedicated breaker. Follow local electrical codes.
- Vacuum and Charge: Evacuate system with vacuum pump and charge with specified refrigerant amount.
- Test Run: Test all functions including cooling, heating, fan modes, and remote control operation.
Specifications
| Model Series | MSP-12HRN1 |
| Type | Split System Air Conditioner |
| Color | White / Silver |
| Cooling Capacity | 12000 BTU/h |
| Heating Capacity | 13000 BTU/h |
| Power Supply | 220-240V, 50Hz, 1 Phase |
| Energy Rating | A++ (Cooling) / A+ (Heating) |
| Refrigerant | R32 (ECO Friendly) |
| Noise Level (Indoor/Outdoor) | 19 dB / 50 dB |
| Dimensions Indoor (HxWxD) | 29 x 80 x 21 cm |
| Dimensions Outdoor (HxWxD) | 55 x 78 x 29 cm |
| Weight (Indoor/Outdoor) | 9 kg / 28 kg |
| Air Flow (Indoor) | 12 m³/min |
Warranty Information
- Full Warranty: 2 years parts and labor
- Compressor Warranty: 5 years on rotary compressor
- Extended Warranty: Optional 5-year extended warranty available
For warranty service, contact Mirage Customer Service at 1-800-555-MIRAGE or visit MirageAC.com
Key Features
Inverter Technology
Advanced DC inverter compressor adjusts cooling/heating capacity to maintain precise temperature control while reducing energy consumption by up to 40%.
Wi-Fi Smart Control
Connect to home Wi-Fi network for remote control via smartphone app. Schedule operations, monitor energy usage, and receive maintenance alerts.
4D Auto Swing
Multi-directional air flow system distributes air evenly throughout the room, eliminating hot/cold spots and ensuring consistent comfort.
Self-Cleaning Function
Automatically cleans indoor unit heat exchanger to prevent mold and bacteria growth, ensuring healthier air quality and maintaining efficiency.
Eco Mode
Intelligent energy-saving mode optimizes operation to reduce power consumption while maintaining comfort levels.
Quiet Operation
Specialized noise reduction technology ensures ultra-quiet operation as low as 19 dB, quieter than a whisper.
Operating Modes
Cool Mode
Standard cooling operation with adjustable temperature and fan speed settings
Heat Mode
Heating operation with efficient heat pump technology for winter comfort
Dry Mode
Dehumidification function reduces humidity without overcooling the room
Fan Mode
Circulates air without cooling or heating, with multiple fan speed options
Auto Mode
Intelligent mode automatically selects cooling or heating based on room temperature
Sleep Mode
Gradually adjusts temperature and reduces fan speed for undisturbed sleep
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit not turning on | Power outage, circuit breaker tripped, remote control batteries dead | Check power supply, reset breaker, replace remote batteries |
| Poor cooling/heating | Dirty filters, blocked airflow, refrigerant leak, outdoor unit obstructed | Clean filters, clear obstructions, check for leaks, clear outdoor unit area |
| Water dripping indoors | Clogged drain pipe, improper installation slope, dirty filters | Clear drain pipe, ensure proper slope, clean filters |
| Unusual noises | Loose parts, debris in fan, improper installation | Tighten components, clear debris, check installation |
| Foul odor | Dirty filters, mold growth in indoor unit | Clean filters, run self-cleaning cycle, professional cleaning if needed |
| Remote not working | Dead batteries, signal obstruction, remote sensor issue | Replace batteries, ensure line of sight, check sensor window |
Error Codes
- E1: Room temperature sensor failure - Check sensor connection
- E2: Pipe temperature sensor failure - Check sensor connection
- E3: Communication error - Check wiring between indoor/outdoor units
- E4: High pressure protection - Check for blocked condenser, dirty filters
- E5: Low pressure protection - Check for refrigerant leak
- E6: Compressor overload - Allow unit to cool down, check voltage
- E7: Fan motor error - Check fan motor and connections
- E8: Water full protection - Check drain system
Manual Downloads
Current Model Manuals
MSP-12HRN1
12000 BTU Inverter Split AC
MSP-18HRN1
18000 BTU Inverter Split AC
MSP-24HRN1
24000 BTU Inverter Split AC
MSP-09HRN1
9000 BTU Inverter Split AC
Popular Previous Models
MSA-12HSN1
12000 BTU Standard Split AC
MSA-18HSN1
18000 BTU Standard Split AC
MSP-12HRW1
12000 BTU Wi-Fi Split AC
MSA-24HSN1
24000 BTU Standard Split AC