Installation Guide
Tools Needed:
- Adjustable wrench
- Level
- Screwdrivers (flat and Phillips)
- Pipe cutter
- Vacuum pump
- Manifold gauge
Step-by-Step Installation
- Choose Installation Location: Select a location for indoor and outdoor units with proper clearance and structural support.
- Mount Indoor Unit: Install mounting plate on wall, ensuring it's level and secure. Hang indoor unit on plate.
- Install Outdoor Unit: Place outdoor unit on stable, level surface with proper ventilation clearance.
- Connect Refrigerant Pipes: Connect copper pipes between indoor and outdoor units, ensuring proper insulation.
- Electrical Connection: Connect power cables according to wiring diagram. Ensure proper grounding.
- Vacuum and Charge: Evacuate air and moisture from system using vacuum pump, then charge with refrigerant.
- Test Run: Test all functions including cooling, heating, and fan modes to ensure proper operation.
Specifications
| Model Series | TAC-24CHSA/AS |
| Type | Inverter Split System Air Conditioner |
| Color | White / Titanium |
| Cooling Capacity | 24,000 BTU/h |
| Heating Capacity | 26,000 BTU/h |
| Noise Level (Indoor) | 19 dB - 42 dB |
| Control Type | Remote Control with LED Display |
| Energy Rating | A++ (High Efficiency) |
| Power Requirements | 220-240V, 50Hz, 15A |
| Refrigerant | R32 Eco-Friendly |
| Dimensions Indoor (HxWxD) | 29 x 89 x 21 cm |
| Dimensions Outdoor (HxWxD) | 55 x 85 x 31 cm |
| Weight Indoor/Outdoor | 9 kg / 35 kg |
Warranty Information
- Full Warranty: 2 years parts and labor
- Compressor Warranty: 5 years on inverter compressor
- Extended Coverage: Optional 5-year extended warranty available
For warranty service, contact TCL Customer Service at 1-800-555-TCL1 or visit TCL.com
Key Features
Inverter Technology
TCL's advanced inverter compressor adjusts cooling/heating power based on room temperature, providing consistent comfort while saving up to 40% energy compared to conventional units.
Wi-Fi Smart Control
Connect to home Wi-Fi network and control your AC remotely via smartphone app. Schedule operations, monitor energy usage, and receive maintenance alerts.
4D Auto Swing
Wide-angle airflow distribution with automatic vertical and horizontal louvers movement ensures even temperature distribution throughout the room.
Self-Cleaning Function
Automatic cleaning cycle removes moisture from heat exchanger to prevent mold and bacteria growth, ensuring healthier air and better performance.
Sleep Mode
Intelligent sleep mode automatically adjusts temperature and fan speed throughout the night for optimal comfort and energy savings while you sleep.
Turbo Mode
Quick cooling/heating function that operates at maximum capacity for 30 minutes to rapidly reach desired temperature, then returns to normal operation.
Operating Modes Explained
Cool Mode
Standard cooling operation with adjustable temperature from 16°C to 30°C
Heat Mode
Heating operation with adjustable temperature from 16°C to 30°C
Dry Mode
Dehumidification function that removes excess moisture without overcooling
Fan Mode
Circulates air without cooling or heating, with multiple fan speed options
Auto Mode
Automatically selects cooling or heating based on room temperature
Eco Mode
Energy-saving operation that optimizes performance for reduced power consumption
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit won't start | Power issue, remote control batteries dead, circuit breaker tripped | Check power supply, replace remote batteries, reset circuit breaker |
| Poor cooling/heating | Dirty filters, blocked airflow, incorrect temperature setting | Clean filters, clear obstructions, set appropriate temperature |
| Water leaking indoors | Clogged drain pipe, improper installation slope | Clear drain pipe, ensure proper installation angle |
| Unusual noises | Loose parts, debris in fan, vibration | Tighten components, clean fan blades, check mounting |
| Frozen indoor unit | Dirty filters, low refrigerant, fan malfunction | Clean filters, check refrigerant charge, inspect fan motor |
| Remote not working | Dead batteries, signal obstruction, remote damage | Replace batteries, ensure line of sight, check remote |
Error Codes
- E0: Room temperature sensor error - Check indoor sensor
- E1: Indoor unit PCB error - Contact service center
- E2: Outdoor unit communication error - Check wiring connections
- E3: High pressure protection - Check for blockage, clean outdoor unit
- E4: Low pressure protection - Check refrigerant charge
- E5: Compressor overload - Allow unit to cool, check voltage
- E6: Communication error - Check indoor-outdoor wiring
- E7: Outdoor temperature sensor error - Check outdoor sensor
Manual Downloads
Current Model Manuals
TAC-24CHSA/AS
24,000 BTU Inverter Split AC
TAC-18CHSA/AS
18,000 BTU Inverter Split AC
TAC-12CHSA/AS
12,000 BTU Inverter Split AC
TAC-09CHSA/AS
9,000 BTU Inverter Split AC
Popular Previous Models
TAC-24CS/AS
24,000 BTU Standard Split AC
TAC-18CI/AS
18,000 BTU Inverter AC
TAC-12CW/AS
12,000 BTU Window AC
TAC-09CP/AS
9,000 BTU Portable AC