Installation Guide
Tools Needed:
- Window installation kit (included)
- Screwdriver
- Tape measure
- Level
- Scissors or utility knife
Step-by-Step Installation
- Choose Installation Location: Select a location near a window and electrical outlet on a flat, stable surface.
- Prepare Window Kit: Adjust the window bracket to fit your window opening and secure it in place.
- Connect Exhaust Hose: Attach the exhaust hose to the back of the unit and connect the other end to the window bracket.
- Position the Unit: Place the air conditioner on a flat surface, ensuring at least 50cm clearance on all sides for proper airflow.
- Electrical Connection: Plug into a dedicated 220-240V, 50Hz grounded outlet. Do not use extension cords or power strips.
- Seal the Window: Use the provided foam seals to close any gaps around the window bracket to prevent warm air from entering.
- Test Operation: Turn on the unit and run through all modes to ensure proper cooling, dehumidification, and ventilation.
Specifications
| Model Series | RAC-PT1411HHR / RAC-PT1411HCR |
| Type | Portable Air Conditioner |
| Color | White / Silver |
| Cooling Capacity | 14,000 BTU/h |
| Room Coverage | Up to 35 m² |
| Noise Level | 52 dB (Low) / 62 dB (High) |
| Control Type | Digital Display with Remote Control |
| Energy Rating | A (Energy Efficient) |
| Dehumidification Capacity | 1.8 L/hour |
| Power Requirements | 220-240V, 50Hz, 10A |
| Dimensions (HxWxD) | 72 x 42 x 35 cm |
| Weight | 32 kg |
| Refrigerant | R32 (Eco-friendly) |
Warranty Information
- Full Warranty: 2 years parts and labor
- Compressor Warranty: 5 years on rotary compressor
- Additional Coverage: Optional extended warranty available
For warranty service, contact Toshiba Customer Service at 1-800-631-3811 or visit Toshiba-aircon.com
Key Features
Mobile Design with Casters
Four smooth-rolling casters allow easy movement between rooms. No permanent installation required - perfect for apartments and rented spaces.
Auto Swing Louvers
Automatically oscillating vertical and horizontal louvers distribute cool air evenly throughout the room, eliminating hot spots.
3-in-1 Functionality
Combines cooling, dehumidification, and fan functions in one compact unit. Ideal for year-round climate control.
24-Hour Timer
Program the unit to turn on/off automatically at set times. Save energy by cooling rooms only when needed.
Auto Evaporation System
Advanced evaporation technology minimizes water tank emptying. Most moisture is evaporated and exhausted automatically.
Sleep Mode
Quiet operation with gradually increasing temperature settings for comfortable sleeping conditions and energy savings.
Operating Modes Explained
Cool Mode
Standard cooling operation with adjustable temperature settings from 16°C to 30°C
Dry Mode
Dehumidification function that removes excess moisture without overcooling the room
Fan Mode
Circulates air without cooling. Three speed settings: Low, Medium, High
Auto Mode
Intelligent operation that automatically selects cooling or fan mode based on room temperature
Turbo Mode
Maximum cooling power for quick temperature reduction on extremely hot days
Eco Mode
Energy-saving operation that optimizes performance while minimizing power consumption
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit not turning on | Power issue, full water tank, timer set | Check power supply, empty water tank, check timer settings |
| Poor cooling performance | Dirty filters, exhaust hose blocked, room too large | Clean air filters, check hose for obstructions, ensure room size matches capacity |
| Water leakage | Full water tank, improper installation, drain plug not inserted | Empty water tank, check installation angle, ensure drain plug is properly inserted |
| Unusual noises | Loose parts, foreign objects, uneven surface | Check for loose components, remove foreign objects, place on level surface |
| Error code displayed | Sensor failure, system malfunction | Refer to error code list below, contact service if problem persists |
| Remote control not working | Dead batteries, signal obstruction, distance too far | Replace batteries, ensure clear line of sight, operate within 7 meters |
Error Codes
- E1: Room temperature sensor error - Contact service center
- E2: Evaporator temperature sensor error - Contact service center
- E3: Condenser temperature sensor error - Contact service center
- P1: Water tank full - Empty water collection tank
- P2: Overheating protection - Turn off for 30 minutes, check air filters
- P3: Electrical malfunction - Unplug and contact service center
Manual Downloads
Current Model Manuals
RAC-PT1411HHR
14,000 BTU Portable AC (Heat & Cool)
RAC-PT1411HCR
14,000 BTU Portable AC (Cool Only)
RAC-PT1211HHR
12,000 BTU Portable AC (Heat & Cool)
RAC-PT1011HCR
10,000 BTU Portable AC (Cool Only)
Popular Previous Models
RAC-PK1412HHR
14,000 BTU Portable AC with Wi-Fi
RAC-PT1010HCR
10,000 BTU Portable AC
RAC-PT0810HCR
8,000 BTU Portable AC
RAC-PT1410HHR
14,000 BTU Dual Hose Portable